Toggle navigation
Dave's Patent Content Factory
Applications
(current)
Terms
Paragraphs
Claims
Docket
logout
about
Edit Paragraph
Application
2380.2.01
US-20150012794-A1
US-20150205664-A1
US-20100023800-A1
US-8737141-A1
US-10157004-B2
US10007433A1
US-9159419-B2
US-10114589-A1
US-10134728-A1
US-20200065270-A1
US-10637533-B2
US-9927986-A1
US-8380915-A1
US-9159419-A1
US-9208071-A1
US-20200098728-A1
US-10643676-A1
US-10468073-B2
US-10283200-A1
US-10461965-B1
US-20130279232-A1
US-8892980-B2
US9632727A1
US10558561A1
US20100023800A1
US7230213A1
OPT-9
FLO-2
FLO-5PROV
ONSO3175(B) - Onsemi378
ONSO3305US - Onsemi346
GTS-3DES
FLO-4
US8762658B2
US8533406B2
US9632727B2
KMN-1PROV
PAT-2
PER-8 PROV
PER-9 PROV
INS-4PROV
HAR-1
CES-16
NXT-5PROV NXT-5, 6, 7, 8
IPP-0051-US14 cross roads
FLO-7PROV
IMI-5PROV
IPP-0050-US35 nextremity
VIL-12
OPT-13
TOY-1
US10998041B1
FSP1845
US6559866B2
Placeholder App
PER-10
KBR-1 1400.2.623
PER-13PROV
PAT-3
US20030023453
RMS-1DES
SMG-1DES
FLO-5
US10318495
US10133662B2
PER-11
US20140066758
VIL-17
PER-17
JBR-1
PER-12
US11056880
US11302645
US20210407565
US11081191
PON-1PROV, 2PROV, 3PROV
PER-33
RMT-1PROV
PER-32
PER-34
MCC-1
FLO-10
PER-14
PER-19
PER-22
PER-18
PER-24
TMC-PAT-1
DAR-2
PER-23
TMC-PAT-4
PER-16
PER-4 DIV1
PER-20
PER-21
BRT-PAT-1
TMC-PAT-5
TMC-PAT-6PROV
BRT-PAT-2-PROV
TMC-PAT-7-PROV
FPR-PAT-1-PROV
TMC-PAT-8-PROV
RMT-1
DAR-1PROV
DAR-2PROV
PON-1PROV
PON-2PROV
PON-3PROV
PER-18PROV
TMC-1PROV
TMC-2PROV
PER-13PCT
PER-13
PER-16PROV
PER-14PROV
PER-34PROV
TMC-4PROV
TMC-3
PAS-1PROV
VEH-1
PER-29DES
TEST.001
E2E-TEST.001
TEST-001
TEST-002
TEST-003
TEST-004
ZED006
FSP1011
Application Number
11952091
Matter Number
Paragraph Number
185
Content
A read operation is similar to the write example above. During a read operation, typically the bus arbiter 420, or other component of the bank interleave controller 344, receives data and corresponding status information and sends the data to the read data pipeline 108 while sending the status information on to the control and status registers 340. Typically, a read data command forwarded from bus arbiter 420 to the storage bus controller 348 will cause the MUX 350 to gate the read data on storage I/O bus 210 to the read data pipeline 108 and send status information to the appropriate control and status registers 340 through the status MUX 422.
Reference Case 1
Reference Case 2
Notes
Added by DJM 3 2021
Raw Data
<w:p><w:pPr><w:pStyle w:val="TPSBody100"/></w:pPr><w:r><w:t xml:space="preserve">A read operation is similar to the write example above. During a read operation, typically the bus arbiter </w:t></w:r><w:r><w:t>420</w:t></w:r><w:r><w:t xml:space="preserve">, or other component of the bank interleave controller </w:t></w:r><w:r><w:t>344</w:t></w:r><w:r><w:t xml:space="preserve">, receives data and corresponding status information and sends the data to the read data pipeline </w:t></w:r><w:r><w:t>108</w:t></w:r><w:r><w:t xml:space="preserve"> while sending the status information on to the control and status registers </w:t></w:r><w:r><w:t>340</w:t></w:r><w:r><w:t xml:space="preserve">. Typically, a read data command forwarded from bus arbiter </w:t></w:r><w:r><w:t>420</w:t></w:r><w:r><w:t xml:space="preserve"> to the storage bus controller </w:t></w:r><w:r><w:t>348</w:t></w:r><w:r><w:t xml:space="preserve"> will cause the MUX </w:t></w:r><w:r><w:t>350</w:t></w:r><w:r><w:t xml:space="preserve"> to gate the read data on storage I/O bus </w:t></w:r><w:r><w:t>210</w:t></w:r><w:r><w:t xml:space="preserve"> to the read data pipeline </w:t></w:r><w:r><w:t>108</w:t></w:r><w:r><w:t xml:space="preserve"> and send status information to the appropriate control and status registers </w:t></w:r><w:r><w:t>340</w:t></w:r><w:r><w:t xml:space="preserve"> through the status MUX </w:t></w:r><w:r><w:t>422</w:t></w:r><w:r><w:t>.</w:t></w:r></w:p>
Submit