Deprecated: Since 5.0.0: Calling Table::get() with options array is deprecated. Use named arguments instead. /application/src/Controller/ParagraphsController.php, line: 67 You can disable all deprecation warnings by setting `Error.errorLevel` to `E_ALL & ~E_USER_DEPRECATED`. Adding `src/Controller/ParagraphsController.php` to `Error.ignoredDeprecationPaths` in your `config/app.php` config will mute deprecations from that file only. in /application/vendor/cakephp/cakephp/src/Core/functions.php on line 377

Warning: Unable to emit headers. Headers sent in file=/application/vendor/cakephp/cakephp/src/Core/functions.php line=377 in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 65

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 158

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 228
Dave's PCF WIP: Paragraphs

7921

Application Patient Specific cutting guide
Matter Number PER-10 Reference Case 1 PER-10
Created 2/25/22, 12:00 AM Modified 2/25/22, 12:00 AM
Application Number
Paragraph Number

226

Content

FIG. 20 illustrates one example of a cutting guide 1900 coupled to the bones using a proximal bone attachment feature 1952 and a distal bone attachment feature 1954. In the illustrated embodiment, the proximal bone attachment feature 1952 includes at least one hole 1950 and a fastener and the distal bone attachment feature 1954 includes at least one hole 1950 and a fastener. In FIG. 20 the fasteners are K-wires. Advantageously, the proximal bone attachment feature 1952 and the distal bone attachment feature 1954 each include at least two holes 1950, each with a K-wire passing through the hole 1950 and into bone facing the inferior side 1922. Using two holes 1950 and two fasteners ensures a stable coupling between the cutting guide 1900 and the bone(s). Advantageously, in certain embodiments, the two holes 1950 of the proximal bone attachment feature 1952 and distal bone attachment feature 1954 are align such that inserted K-wires are parallel to each other. Among other benefits, parallel K-wires of each of the proximal bone attachment feature 1952 and distal bone attachment feature 1954 prevent the cutting guide 1900 from pivoting around one of the K-wires of a proximal bone attachment feature 1952 or a distal bone attachment feature 1954.

Notes

Added by DJM 2 2022