Deprecated: Since 5.0.0: Calling Table::get() with options array is deprecated. Use named arguments instead. /application/src/Controller/ParagraphsController.php, line: 67 You can disable all deprecation warnings by setting `Error.errorLevel` to `E_ALL & ~E_USER_DEPRECATED`. Adding `src/Controller/ParagraphsController.php` to `Error.ignoredDeprecationPaths` in your `config/app.php` config will mute deprecations from that file only. in /application/vendor/cakephp/cakephp/src/Core/functions.php on line 377

Warning: Unable to emit headers. Headers sent in file=/application/vendor/cakephp/cakephp/src/Core/functions.php line=377 in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 65

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 158

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 228
Dave's PCF WIP: Paragraphs

7227

Application Knee Prosthesis
Matter Number OPT-13 Reference Case 1 OPT-13
Created 1/25/22, 12:00 AM Modified 1/25/22, 12:00 AM
Application Number
Paragraph Number

175

Content

In one embodiment, the tibial articulation surface 2412 is configured to include one or more of a medial tibial compartment 2413, a lateral tibial compartment 2414, a medial articulation surface 2420, a lateral articulation surface 2421, and/or high and/or low points within the medial articulation surface 2420, and/or the lateral articulation surface 2421 to remediate a condition of the knee joint into which the knee prosthesis system 3000 deployed. In one embodiment, the tibial articulation surface 2412 contour and/or features adjust mediolateral stability during flexion of a first knee joint having a varus condition: is a varus knee joint. In one embodiment, a tibial articulation surface 2412 of the tibial insert 2910b may adjust mediolateral stability by increasing constraint on a lateral collateral ligament of the first knee joint and decreases tension on a medial collateral ligament of the first knee joint.

Notes

Added by DJM 1 2022