Deprecated: Since 5.0.0: Calling Table::get() with options array is deprecated. Use named arguments instead. /application/src/Controller/ParagraphsController.php, line: 67 You can disable all deprecation warnings by setting `Error.errorLevel` to `E_ALL & ~E_USER_DEPRECATED`. Adding `src/Controller/ParagraphsController.php` to `Error.ignoredDeprecationPaths` in your `config/app.php` config will mute deprecations from that file only. in /application/vendor/cakephp/cakephp/src/Core/functions.php on line 377

Warning: Unable to emit headers. Headers sent in file=/application/vendor/cakephp/cakephp/src/Core/functions.php line=377 in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 65

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 158

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 228
Dave's PCF WIP: Paragraphs

6963

Application Angle and Distance measuring device
Matter Number TOY-1 Reference Case 1 TOY-1
Created 1/19/22, 12:00 AM Modified 1/19/22, 12:00 AM
Application Number
Paragraph Number

141

Content

The surgical device 200c may be used with a method for intraoperatively confirming a pedicle screw insertion trajectory on a vertebra of a patient. The method may start by positioning a patient on a table for a spinal surgery procedure such that a coronal plane of the patient is parallel to a floor supporting the table. Next, the surgical device 200c may be calibrated by positioning the surgical device 200c superficial to skin of the patient and substantially centering the surgical device 200c above the patient’s spine. Next, the surgical device 200c may be calibrated to set a reference axis for the hand-held surgical device relative to the patient’s spine. Next, a distal end 214 (e.g., bone probe 216) of the shaft 210 and/or surgical device 200c is placed on a surface of a pedicle of a vertebra of the patient’s spine.

Notes

Added by DJM 1 2022