Deprecated: Since 5.0.0: Calling Table::get() with options array is deprecated. Use named arguments instead. /application/src/Controller/ParagraphsController.php, line: 67 You can disable all deprecation warnings by setting `Error.errorLevel` to `E_ALL & ~E_USER_DEPRECATED`. Adding `src/Controller/ParagraphsController.php` to `Error.ignoredDeprecationPaths` in your `config/app.php` config will mute deprecations from that file only. in /application/vendor/cakephp/cakephp/src/Core/functions.php on line 377

Warning: Unable to emit headers. Headers sent in file=/application/vendor/cakephp/cakephp/src/Core/functions.php line=377 in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 65

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 158

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 228
Dave's PCF WIP: Paragraphs

5310

Application Cortical suture or tissue fixation device
Matter Number HAR-1PROV Reference Case 1 HAR-1PROV
Created 9/2/21, 12:00 AM Modified 9/2/21, 12:00 AM
Application Number
Paragraph Number

25

Content

A pushing, pulling, or tension force applied to the tissue 114 in the first direction 116 can/will cause the tissue 114 to move through the one-way tissue engagement feature 110 in the first direction 116. Conversely, a pushing, pulling, or tension force applied to the tissue 114 in the second direction 118 can/will not cause the tissue 114 to move through the one-way tissue engagement feature 110 in the second direction 118. Instead, movement of the tissue 114 in the second direction 118 will be stopped, retained, prevented, or mitigated by the one-way tissue engagement feature 110 of the fixation device 100. In certain embodiments, the one-way tissue engagement feature 110 engages with the tissue 114 such that a failure or tear of the tissue 114 within the one-way tissue engagement feature 110 may be the only way to remove the one-way tissue engagement feature 110 from the tissue 114.

Notes

Added by DJM 9 2021