Deprecated: Since 5.0.0: Calling Table::get() with options array is deprecated. Use named arguments instead. /application/src/Controller/ParagraphsController.php, line: 67 You can disable all deprecation warnings by setting `Error.errorLevel` to `E_ALL & ~E_USER_DEPRECATED`. Adding `src/Controller/ParagraphsController.php` to `Error.ignoredDeprecationPaths` in your `config/app.php` config will mute deprecations from that file only. in /application/vendor/cakephp/cakephp/src/Core/functions.php on line 377

Warning: Unable to emit headers. Headers sent in file=/application/vendor/cakephp/cakephp/src/Core/functions.php line=377 in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 65

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 158

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 228
Dave's PCF WIP: Paragraphs

4827

Application BONE FIXATION DEVICES, SYSTEMS, AND METHODS
Matter Number NXT-5PROV Reference Case 1 NXT-5PROV
Created 8/16/21, 12:00 AM Modified 8/16/21, 12:00 AM
Application Number
Paragraph Number

106

Content

Figure 5A is a perspective view of a medial bone plate 500a deployed on a long bone, according to one embodiment. The medial bone plate 500a may have structures, features, and functions, operations, and configuration similar to that of the medial bone plate 400 described in relation to FIG. 4A-4E. Accordingly, the medial bone plate 500a may include a proximal end 502, distal end 504, body 506, one or more arms 508, one or more fastener openings 514, a fixation feature 516, a front surface 518, a back surface 520 (not shown), and one or more elbows 522. In the illustrated embodiment, the medial bone plate 500a has a longer body 506 such that the arms 508 are positioned above a fracture 524.

Notes

Added by DJM 8 2021