Deprecated: Since 5.0.0: Calling Table::get() with options array is deprecated. Use named arguments instead. /application/src/Controller/ParagraphsController.php, line: 67 You can disable all deprecation warnings by setting `Error.errorLevel` to `E_ALL & ~E_USER_DEPRECATED`. Adding `src/Controller/ParagraphsController.php` to `Error.ignoredDeprecationPaths` in your `config/app.php` config will mute deprecations from that file only. in /application/vendor/cakephp/cakephp/src/Core/functions.php on line 377

Warning: Unable to emit headers. Headers sent in file=/application/vendor/cakephp/cakephp/src/Core/functions.php line=377 in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 65

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 158

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 228
Dave's PCF WIP: Paragraphs

4156

Application CERVICAL PLATE INCLUDING SCREW LOCKING MECHANISM UTILIZING RADIAL GROOVES
Matter Number FLO-4 Reference Case 1 FLO-4
Created 5/1/21, 12:00 AM Modified 5/1/21, 12:00 AM
Application Number
Paragraph Number

4

Content

To achieve the foregoing, and in accordance with the disclosure as embodied and broadly described herein, an implant assembly may be provided. One general aspect of the implant assembly can include a screw that may also include a head which may include a head feature which may include one of a ridge and a radial groove. The implant assembly may also include an implant securable to a bone of a patient with the screw. The implant may include: a bone plate that may have a screw opening sized to receive the screw. The implant may also include a rotatable structure coupled to the bone plate such that the rotatable structure is rotatable between a locked orientation and an unlocked orientation, the rotatable structure may include: a top surface; a bottom surface that may include a lock feature that may include the other of the ridge and the radial groove. The implant assembly may also include where the lock feature is positioned such that: with the rotatable structure in the locked orientation, the lock feature engages the head feature, thereby restricting rotation of the screw within the screw opening; and with the rotatable structure in the unlocked orientation, the lock feature disengages from the head feature, thereby permitting rotation of the screw within the screw opening.

Notes

Added by DJM 5 2021