Deprecated: Since 5.0.0: Calling Table::get() with options array is deprecated. Use named arguments instead. /application/src/Controller/ParagraphsController.php, line: 67 You can disable all deprecation warnings by setting `Error.errorLevel` to `E_ALL & ~E_USER_DEPRECATED`. Adding `src/Controller/ParagraphsController.php` to `Error.ignoredDeprecationPaths` in your `config/app.php` config will mute deprecations from that file only. in /application/vendor/cakephp/cakephp/src/Core/functions.php on line 377

Warning: Unable to emit headers. Headers sent in file=/application/vendor/cakephp/cakephp/src/Core/functions.php line=377 in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 65

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 158

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 228
Dave's PCF WIP: Paragraphs

2071

Application EXPANDABLE INTERVERTEBRAL IMPLANT SYSTEM AND METHOD
Matter Number FLO-5PROV Reference Case 1 FLO-5PROV
Created 2/18/21, 12:00 AM Modified 2/18/21, 12:00 AM
Application Number
Paragraph Number

85

Content

The drive member 580 is configured to engage a drive recess 244 (See FIG. 2H) of a screw member 118. Accordingly, the drive member 580 is configured to have a shape and configuration that matches the type of drive recess 244 of the screw member 118. Depending on the type of recess 244, the drive member 580 has a corresponding type and shape such as a slot to fit a slotted recess 244, a torx end to fit a torx recess 244, a Philips end to fit a Philips recess 244, and the like. Of course, those of skill in the art recognize that the shape and configuration of the drive member 580 and the recess 244 can be reversed and thus comprise an embodiment within the scope of the present disclosure. The drive member 580 is configured to connect to the shaft 570 and fit within the inserter fork 430 such that the drive member 580 seats within the drive recess 244 when the expandable intervertebral implant is attached to the inserter 400.

Notes

Added by DJM 2 2021