Deprecated: Since 5.0.0: Calling Table::get() with options array is deprecated. Use named arguments instead. /application/src/Controller/ParagraphsController.php, line: 67 You can disable all deprecation warnings by setting `Error.errorLevel` to `E_ALL & ~E_USER_DEPRECATED`. Adding `src/Controller/ParagraphsController.php` to `Error.ignoredDeprecationPaths` in your `config/app.php` config will mute deprecations from that file only. in /application/vendor/cakephp/cakephp/src/Core/functions.php on line 377

Warning: Unable to emit headers. Headers sent in file=/application/vendor/cakephp/cakephp/src/Core/functions.php line=377 in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 65

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 158

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 228
Dave's PCF WIP: Paragraphs

2050

Application EXPANDABLE INTERVERTEBRAL IMPLANT SYSTEM AND METHOD
Matter Number FLO-5PROV Reference Case 1 FLO-5PROV
Created 2/18/21, 12:00 AM Modified 2/18/21, 12:00 AM
Application Number
Paragraph Number

64

Content

By way of example, angles between the ramps 214, 222 and wedges 114, 116 can be selected such that the upper endplate 110 moves uniformly vertically relative to the lower endplate 112. In another embodiment, the the ramps 214, 222, wedges 114, 116, and/or angles between them are configured such that a ratio of the first height H1 to the second height H2 (See FIG. 1C, 1D) changes as the exemplary expandable intervertebral implant 100 transitions from a collapsed configuration to a partially expanded configuration or expanded configuration. For example, in an expanded configuration H1 and H2 can be substantially the same.

Notes

Added by DJM 2 2021