Deprecated: Since 5.0.0: Calling Table::get() with options array is deprecated. Use named arguments instead. /application/src/Controller/ParagraphsController.php, line: 67 You can disable all deprecation warnings by setting `Error.errorLevel` to `E_ALL & ~E_USER_DEPRECATED`. Adding `src/Controller/ParagraphsController.php` to `Error.ignoredDeprecationPaths` in your `config/app.php` config will mute deprecations from that file only. in /application/vendor/cakephp/cakephp/src/Core/functions.php on line 377

Warning: Unable to emit headers. Headers sent in file=/application/vendor/cakephp/cakephp/src/Core/functions.php line=377 in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 65

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 158

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 228
Dave's PCF WIP: Paragraphs

1891

Application EXPANDABLE INTERVERTEBRAL IMPLANT
Matter Number FLO-2 Reference Case 1 FLO-2
Created 2/18/21, 12:00 AM Modified 2/18/21, 12:00 AM
Application Number

17/129,237

Paragraph Number

83

Content

Figure 5A is an exploded view of the expandable intervertebral implant 300 of Figure 3A with the screw member 400 of Figure 4A. The expandable intervertebral implant 300 is in a collapsed configuration. Figure 5A illustrates an expansion mechanism 160 embodied as a screw member 400 configured to engage internal threads 154 and seat within the opening 150 at the proximal end 170. In certain embodiments, the internal threads 154 may be considered a part of the expansion mechanism 160. Alternatively, or in addition, certain embodiments of the expansion mechanism 160 may not require internal threads 154.

Notes

Added by DJM 2 2021