Deprecated: Since 5.0.0: Calling Table::get() with options array is deprecated. Use named arguments instead. /application/src/Controller/ParagraphsController.php, line: 67 You can disable all deprecation warnings by setting `Error.errorLevel` to `E_ALL & ~E_USER_DEPRECATED`. Adding `src/Controller/ParagraphsController.php` to `Error.ignoredDeprecationPaths` in your `config/app.php` config will mute deprecations from that file only. in /application/vendor/cakephp/cakephp/src/Core/functions.php on line 377

Warning: Unable to emit headers. Headers sent in file=/application/vendor/cakephp/cakephp/src/Core/functions.php line=377 in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 65

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 158

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 228
Dave's PCF WIP: Paragraphs

1823

Application EXPANDABLE INTERVERTEBRAL IMPLANT
Matter Number FLO-2 Reference Case 1 FLO-2
Created 2/18/21, 12:00 AM Modified 2/18/21, 12:00 AM
Application Number

17/129,237

Paragraph Number

15

Content

The expandable intervertebral implant may have a proximal end and a distal end. The first mesh may span the first wall from the first upper side to the first lower side and from the proximal end to the distal end of the expandable intervertebral implant. The second mesh may span the second wall from the second upper side to the second lower side and from the proximal end to the distal end of the expandable intervertebral implant. The upper mesh may span the upper plate from the first upper side to the second upper side and from the proximal end to the distal end of the expandable intervertebral implant. The lower mesh may span the lower plate from the first lower side to the second lower side and from the proximal end to the distal end of the expandable intervertebral implant.

Notes

Added by DJM 2 2021