Deprecated: Since 5.0.0: Calling Table::get() with options array is deprecated. Use named arguments instead. /application/src/Controller/ParagraphsController.php, line: 67 You can disable all deprecation warnings by setting `Error.errorLevel` to `E_ALL & ~E_USER_DEPRECATED`. Adding `src/Controller/ParagraphsController.php` to `Error.ignoredDeprecationPaths` in your `config/app.php` config will mute deprecations from that file only. in /application/vendor/cakephp/cakephp/src/Core/functions.php on line 377

Warning: Unable to emit headers. Headers sent in file=/application/vendor/cakephp/cakephp/src/Core/functions.php line=377 in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 65

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 158

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 228
Dave's PCF WIP: Paragraphs

15217

Application APPARATUS, SYSTEM, AND METHOD FOR GENERATING PATIENT-SPECIFIC IMPLANTS AND/OR INSTRUMENTATION FOR OSTEOTOMIES
Matter Number PER-12 Reference Case 1 PER-12
Created 1/6/24, 10:03 PM Modified 1/6/24, 10:03 PM
Application Number
Paragraph Number

377

Content

Advantageously, fasteners 2216 (e.g., posterior pin 2220 and/or anterior pin 2222) deployed using the pin guide(s) 2200 may be used for subsequent steps in a surgical procedure. In one embodiment, the osteotomy system 2000 may include a positioning guide 2300 as one of the complementary components 1930. In one embodiment, for example, a posterior pin 2220 deployed by way of a posterior pin guide 2202 and an anterior pin 2222 deployed by way of an anterior pin guide 2204 are configured to receive a positioning guide 2300. In certain embodiments, depending on how various components of the osteotomy system 2000 are designed and/or fabricated a positioning guide 2300 may serve to position a posterior bone fragment 2114 and/or an anterior bone fragment 2116, reduce an osteotomy, and/or compress two bone fragments together. Alternatively, or in addition, the positioning guide 2300 may also serve as a correction guide, a rotation guide, an alignment guide, and/or the like.

Notes

Added by DJM Jan 2024