Deprecated: Since 5.0.0: Calling Table::get() with options array is deprecated. Use named arguments instead. /application/src/Controller/ParagraphsController.php, line: 67 You can disable all deprecation warnings by setting `Error.errorLevel` to `E_ALL & ~E_USER_DEPRECATED`. Adding `src/Controller/ParagraphsController.php` to `Error.ignoredDeprecationPaths` in your `config/app.php` config will mute deprecations from that file only. in /application/vendor/cakephp/cakephp/src/Core/functions.php on line 377

Warning: Unable to emit headers. Headers sent in file=/application/vendor/cakephp/cakephp/src/Core/functions.php line=377 in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 65

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 158

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191
Dave's PCF WIP: Paragraphs

15122

Application APPARATUS, SYSTEM, AND METHOD FOR GENERATING PATIENT-SPECIFIC IMPLANTS AND/OR INSTRUMENTATION FOR OSTEOTOMIES
Matter Number PER-12 Reference Case 1 PER-12
Created 1/6/24, 10:03 PM Modified 1/6/24, 10:03 PM
Application Number
Paragraph Number

282

Content

The complementary components 1930 serve to assist a surgeon during one or more steps of an osteotomy procedure. Those of skill in the art appreciate that a number of components can serve as complementary components 1930. Examples of complementary components 1930 include, but are not limited to, an alignment guide 1940, a rotation guide 1950, a correction guide 1960, a compression guide 1970, a positioning guide 1980, a fixation guide 1990, one or more pin guides 1994, and one or more implants 1996. In general, the complementary components 1930 serve to assist a surgeon in performing the function included in the name of the complementary component 1930. Thus, an alignment guide 1940 can help a surgeon align bones, parts of bones, or other parts of a patient as part of an osteotomy procedure. A rotation guide 1950 can help a surgeon rotate one or more bones, parts of bones, or other parts of a patient as part of an osteotomy procedure.

Notes

Added by DJM Jan 2024