Deprecated: Since 5.0.0: Calling Table::get() with options array is deprecated. Use named arguments instead. /application/src/Controller/ParagraphsController.php, line: 67 You can disable all deprecation warnings by setting `Error.errorLevel` to `E_ALL & ~E_USER_DEPRECATED`. Adding `src/Controller/ParagraphsController.php` to `Error.ignoredDeprecationPaths` in your `config/app.php` config will mute deprecations from that file only. in /application/vendor/cakephp/cakephp/src/Core/functions.php on line 377

Warning: Unable to emit headers. Headers sent in file=/application/vendor/cakephp/cakephp/src/Core/functions.php line=377 in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 65

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 158

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 228
Dave's PCF WIP: Paragraphs

14967

Application APPARATUS, SYSTEM, AND METHOD FOR GENERATING PATIENT-SPECIFIC IMPLANTS AND/OR INSTRUMENTATION FOR OSTEOTOMIES
Matter Number PER-12 Reference Case 1 PER-12
Created 1/6/24, 10:03 PM Modified 1/6/24, 10:03 PM
Application Number
Paragraph Number

127

Content

Accordingly, in the illustrated embodiment, the cutting guide 300 may include one member of a coupler 410 configured to engage a corresponding member of the coupler coupled to an alignment guide 420. Those of skill in the art appreciate that various designs of a coupler may be used. In the illustrated embodiment, the coupler 410 includes an opening 412 (See Figure 20) that may extend from the superior side 320 into the body 310 through to the inferior side 322 and a post 414. In one embodiment, the opening 412 may include one of the slots, such as second slot 370. The post 414 may include an engagement member 416.

Notes

Added by DJM Jan 2024