Deprecated: Since 5.0.0: Calling Table::get() with options array is deprecated. Use named arguments instead. /application/src/Controller/ParagraphsController.php, line: 67 You can disable all deprecation warnings by setting `Error.errorLevel` to `E_ALL & ~E_USER_DEPRECATED`. Adding `src/Controller/ParagraphsController.php` to `Error.ignoredDeprecationPaths` in your `config/app.php` config will mute deprecations from that file only. in /application/vendor/cakephp/cakephp/src/Core/functions.php on line 377

Warning: Unable to emit headers. Headers sent in file=/application/vendor/cakephp/cakephp/src/Core/functions.php line=377 in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 65

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 158

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 191

Warning: Cannot modify header information - headers already sent by (output started at /application/vendor/cakephp/cakephp/src/Core/functions.php:377) in /application/vendor/cakephp/cakephp/src/Http/ResponseEmitter.php on line 228
Dave's PCF WIP: Paragraphs

14232

Application Tendon Trajectory Guide
Matter Number PER-33 Reference Case 1 PER-33
Created 1/6/24, 9:58 PM Modified 1/6/24, 9:58 PM
Application Number
Paragraph Number

249

Content

A reduction guide 760 can help a surgeon position and/or orient one or more bones, parts of bones, or other parts of a patient as part of a procedure in order to reduce the bone, bones, bone parts, or other parts and/or in order to position and/or orient the bone, bones, bone parts, or other parts to a desired position and/or orientation. In certain embodiments, aspects and/or features of a reduction guide 760 can be integrated into one or more other components of a system 700, such as components of the complementary components 730. A compression guide 770 can help a surgeon compress one or more bones, parts of bones, or other parts of a patient together or against an implant as part of a procedure. In certain embodiments, compression guide 770 can be a separate instrument such as a compressor and/or a combined compressor/distractor. The compressor / distractor can be used to compress two or more cut faces formed by an osteotomy until fixation is deployed or distract bones or parts of bones involved in a procedure. In certain embodiments, a compression guide 770 may serve a dual purpose as both a compression guide 770 and as a positioning guide 780. The same instrument may be used to both translate and/or rotate bones or bone fragments and compress two or more cut faces formed by an osteotomy until fixation can be deployed.

Notes

Added by DJM Jan 2024