Toggle navigation
Dave's Patent Content Factory
Applications
(current)
Terms
Paragraphs
Claims
Docket
logout
about
Edit Paragraph
Application
2380.2.01
US-20150012794-A1
US-20150205664-A1
US-20100023800-A1
US-8737141-A1
US-10157004-B2
US10007433A1
US-9159419-B2
US-10114589-A1
US-10134728-A1
US-20200065270-A1
US-10637533-B2
US-9927986-A1
US-8380915-A1
US-9159419-A1
US-9208071-A1
US-20200098728-A1
US-10643676-A1
US-10468073-B2
US-10283200-A1
US-10461965-B1
US-20130279232-A1
US-8892980-B2
US9632727A1
US10558561A1
US20100023800A1
US7230213A1
OPT-9
FLO-2
FLO-5PROV
ONSO3175(B) - Onsemi378
ONSO3305US - Onsemi346
GTS-3DES
FLO-4
US8762658B2
US8533406B2
US9632727B2
KMN-1PROV
PAT-2
PER-8 PROV
PER-9 PROV
INS-4PROV
HAR-1
CES-16
NXT-5PROV NXT-5, 6, 7, 8
IPP-0051-US14 cross roads
FLO-7PROV
IMI-5PROV
IPP-0050-US35 nextremity
VIL-12
OPT-13
TOY-1
US10998041B1
FSP1845
US6559866B2
Placeholder App
PER-10
KBR-1 1400.2.623
PER-13PROV
PAT-3
US20030023453
RMS-1DES
SMG-1DES
FLO-5
US10318495
US10133662B2
PER-11
US20140066758
VIL-17
PER-17
JBR-1
PER-12
US11056880
US11302645
US20210407565
US11081191
PON-1PROV, 2PROV, 3PROV
PER-33
RMT-1PROV
PER-32
PER-34
MCC-1
FLO-10
PER-14
PER-19
PER-22
PER-18
PER-24
TMC-PAT-1
DAR-2
PER-23
TMC-PAT-4
PER-16
PER-4 DIV1
PER-20
PER-21
BRT-PAT-1
TMC-PAT-5
TMC-PAT-6PROV
BRT-PAT-2-PROV
TMC-PAT-7-PROV
FPR-PAT-1-PROV
TMC-PAT-8-PROV
RMT-1
DAR-1PROV
DAR-2PROV
PON-1PROV
PON-2PROV
PON-3PROV
PER-18PROV
TMC-1PROV
TMC-2PROV
PER-13PCT
PER-13
PER-16PROV
PER-14PROV
PER-34PROV
TMC-4PROV
TMC-3
PAS-1PROV
VEH-1
PER-29DES
TEST.001
E2E-TEST.001
TEST-001
TEST-002
TEST-003
TEST-004
ZED006
FSP1011
Application Number
Matter Number
Paragraph Number
212
Content
Alternatively, or in addition, in certain embodiments, one or both of, the first guide feature and second guide feature may be positioned on, or in, the body 1910 and/or have an orientation based on patient imaging data. The patient imaging data can be used to position and orient one, or both, of the first guide feature and second guide feature such that formation of one, or both, of the first cut surface and the second cut surface and fixation of the two cut surfaces against each other mitigates a condition of the patient. For example, as described in the present disclosure, patient imaging data can be used to generate bone models of bones of the patient. The bone models can be used to determine and/or define contours for a bone engagement surface 1924, a position for a first slot 1960, an orientation for a first slot 1960, a position for a second slot 1970, an orientation for a second slot 1970, as well as other features and attributes of one or more patient specific instruments that can be used in a procedure.
Reference Case 1
Reference Case 2
Notes
Added by DJM 2 2022
Raw Data
<w:p w14:paraId="6970219A" w14:textId="77457597" w:rsidR="0093501E" w:rsidRPr="00A1491D" w:rsidRDefault="00D651C2" w:rsidP="00577C4A"><w:pPr><w:pStyle w:val="NumberedParagraph"/><w:tabs><w:tab w:val="clear" w:pos="360"/><w:tab w:val="num" w:pos="1080"/></w:tabs><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr></w:pPr><w:r w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t xml:space="preserve">Alternatively, or in addition, </w:t></w:r><w:r w:rsidR="002252B2" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t>in certain embodiments</w:t></w:r><w:r w:rsidR="005A2979" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t>, one or both of,</w:t></w:r><w:r w:rsidR="002252B2" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t xml:space="preserve"> </w:t></w:r><w:r w:rsidR="00C50BCF" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t>the first guide feature and second guide feature may be positioned on</w:t></w:r><w:r w:rsidR="00110BA8" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t>,</w:t></w:r><w:r w:rsidR="005A2979" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t xml:space="preserve"> or in</w:t></w:r><w:r w:rsidR="00110BA8" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t>,</w:t></w:r><w:r w:rsidR="00C50BCF" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t xml:space="preserve"> the body 1910 </w:t></w:r><w:r w:rsidR="005A2979" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t xml:space="preserve">and/or have an orientation </w:t></w:r><w:r w:rsidR="000F2D86" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t>based on patient imaging data. The patient imaging data can be used to position and orient one</w:t></w:r><w:r w:rsidR="00110BA8" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t>,</w:t></w:r><w:r w:rsidR="000F2D86" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t xml:space="preserve"> or both</w:t></w:r><w:r w:rsidR="00110BA8" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t>,</w:t></w:r><w:r w:rsidR="000F2D86" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t xml:space="preserve"> of the first guide feature and second guide feature such that formation of one</w:t></w:r><w:r w:rsidR="00110BA8" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t>,</w:t></w:r><w:r w:rsidR="000F2D86" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t xml:space="preserve"> or both</w:t></w:r><w:r w:rsidR="00110BA8" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t>,</w:t></w:r><w:r w:rsidR="000F2D86" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t xml:space="preserve"> of the first cut surface and the second cut surface and </w:t></w:r><w:r w:rsidR="00111402" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t>fixation of the two cut surfaces against each other mitigates a condition of the patient.</w:t></w:r><w:r w:rsidR="008C3711" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t xml:space="preserve"> For example, as described in the present disclosure, patient imaging data can be used to generate bone models of bones of the patient. The bone models can be used to determine </w:t></w:r><w:r w:rsidR="008828F2" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t xml:space="preserve">and/or define </w:t></w:r><w:r w:rsidR="008C3711" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t xml:space="preserve">contours for a </w:t></w:r><w:r w:rsidR="008828F2" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t>bone engagement surface 1924, a position for a first slot 1960, an orientation for a first slot 1960</w:t></w:r><w:r w:rsidR="006C718B" w:rsidRPr="00A1491D"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t>, a position for a second slot 1970, an orientation for a second slot 1970, as well as other features and attributes of one or more patient specific instruments that can be used in a procedure.</w:t></w:r></w:p>
Submit