Toggle navigation
Dave's Patent Content Factory
Applications
(current)
Terms
Paragraphs
Claims
Docket
logout
about
Edit Paragraph
Application
2380.2.01
US-20150012794-A1
US-20150205664-A1
US-20100023800-A1
US-8737141-A1
US-10157004-B2
US10007433A1
US-9159419-B2
US-10114589-A1
US-10134728-A1
US-20200065270-A1
US-10637533-B2
US-9927986-A1
US-8380915-A1
US-9159419-A1
US-9208071-A1
US-20200098728-A1
US-10643676-A1
US-10468073-B2
US-10283200-A1
US-10461965-B1
US-20130279232-A1
US-8892980-B2
US9632727A1
US10558561A1
US20100023800A1
US7230213A1
OPT-9
FLO-2
FLO-5PROV
ONSO3175(B) - Onsemi378
ONSO3305US - Onsemi346
GTS-3DES
FLO-4
US8762658B2
US8533406B2
US9632727B2
KMN-1PROV
PAT-2
PER-8 PROV
PER-9 PROV
INS-4PROV
HAR-1
CES-16
NXT-5PROV NXT-5, 6, 7, 8
IPP-0051-US14 cross roads
FLO-7PROV
IMI-5PROV
IPP-0050-US35 nextremity
VIL-12
OPT-13
TOY-1
US10998041B1
FSP1845
US6559866B2
Placeholder App
PER-10
KBR-1 1400.2.623
PER-13PROV
PAT-3
US20030023453
RMS-1DES
SMG-1DES
FLO-5
US10318495
US10133662B2
PER-11
US20140066758
VIL-17
PER-17
JBR-1
PER-12
US11056880
US11302645
US20210407565
US11081191
PON-1PROV, 2PROV, 3PROV
PER-33
RMT-1PROV
PER-32
PER-34
MCC-1
FLO-10
PER-14
PER-19
PER-22
PER-18
PER-24
TMC-PAT-1
DAR-2
PER-23
TMC-PAT-4
PER-16
PER-4 DIV1
PER-20
PER-21
BRT-PAT-1
TMC-PAT-5
TMC-PAT-6PROV
BRT-PAT-2-PROV
TMC-PAT-7-PROV
FPR-PAT-1-PROV
TMC-PAT-8-PROV
RMT-1
DAR-1PROV
DAR-2PROV
PON-1PROV
PON-2PROV
PON-3PROV
PER-18PROV
TMC-1PROV
TMC-2PROV
PER-13PCT
PER-13
PER-16PROV
PER-14PROV
PER-34PROV
TMC-4PROV
TMC-3
PAS-1PROV
VEH-1
PER-29DES
TEST.001
E2E-TEST.001
TEST-001
TEST-002
TEST-003
TEST-004
ZED006
FSP1011
Application Number
Matter Number
Paragraph Number
47
Content
Once the one-way tissue engagement feature 404 engages the tissue 408 the user has full control of how much tension is placed within the graft. Advantageously, as the tissue 408 pass through the fixation device 400, the fixation device 400 advances along the tissue 408 (e.g., graft) and seats within the bone tunnel 416. This process of moving the fixation device 400 along the tissue 408 may be referred to herein as synching of the fixation device 400. During the steps of synching of the fixation device 400, a surgeon may advantageously check, monitor, and manage tension in the graft with the knee in different positions of flexion. Once sufficient checks of tension are done at one or more flexion positions of the knee, the user may further tighten or synch the fixation device 400. Advantageously, the fixation device 400 secures the tissue 408 with a sufficient force within the bone tunnel 416 to enable the patient to return to regular activities quickly. In one embodiment, the fixation device 400 secures the tissue 408 to retain the tissue 408, such as a graft, when graft experiences 150-500 Newtons (N) of force due to activities of daily living and rehabilitation exercises.
Reference Case 1
Reference Case 2
Notes
Added by DJM 9 2021
Raw Data
<w:p w14:paraId="5B43AB78" w14:textId="3097BA26" w:rsidR="00535B04" w:rsidRPr="00DA56FC" w:rsidRDefault="00535B04" w:rsidP="00535B04"><w:pPr><w:pStyle w:val="NumberedParagraph"/><w:tabs><w:tab w:val="clear" w:pos="360"/><w:tab w:val="num" w:pos="1080"/></w:tabs><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr></w:pPr><w:r w:rsidRPr="00DA56FC"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t xml:space="preserve"> </w:t></w:r><w:r w:rsidR="00716A63" w:rsidRPr="00DA56FC"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t xml:space="preserve">Once the one-way tissue engagement feature 404 engages the tissue 408 the user has full control of how much tension is placed within the graft. Advantageously, as the tissue 408 pass through the fixation device 400, the fixation device 400 advances along the tissue 408 (e.g., graft) and seats within the bone tunnel 416. </w:t></w:r><w:r w:rsidR="00555A0B" w:rsidRPr="00DA56FC"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t>This process of moving the fixation device 400 along the tissue 408 may be referred to herein as synching of the fixation device 400. During the steps of synching of the fixation device 400, a surgeon may advantageously check, monitor, and manage tension in the graft with the knee in different positions of flexion. Once sufficient checks of tension are done at one or more flexion positions of the knee, the user may further tighten or synch the fixation device 400.</w:t></w:r><w:r w:rsidR="00BC4B97" w:rsidRPr="00DA56FC"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t xml:space="preserve"> Advantageously, the fixation device 400 secures the tissue 408 with a sufficient force within the bone tunnel 416 to enable the patient to return to regular activities quickly. In one embodiment, the fixation device 400 secures the tissue 408 to retain the </w:t></w:r><w:r w:rsidR="00BC4B97" w:rsidRPr="00DA56FC"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:lastRenderedPageBreak/><w:t>tissue 408, such as a graft, when graft experiences 150-500 Newtons (N) of force due to activities of daily living and rehabilitation exercises.</w:t></w:r></w:p>
Submit