Toggle navigation
Dave's Patent Content Factory
Applications
(current)
Terms
Paragraphs
Claims
Docket
logout
about
Edit Paragraph
Application
2380.2.01
US-20150012794-A1
US-20150205664-A1
US-20100023800-A1
US-8737141-A1
US-10157004-B2
US10007433A1
US-9159419-B2
US-10114589-A1
US-10134728-A1
US-20200065270-A1
US-10637533-B2
US-9927986-A1
US-8380915-A1
US-9159419-A1
US-9208071-A1
US-20200098728-A1
US-10643676-A1
US-10468073-B2
US-10283200-A1
US-10461965-B1
US-20130279232-A1
US-8892980-B2
US9632727A1
US10558561A1
US20100023800A1
US7230213A1
OPT-9
FLO-2
FLO-5PROV
ONSO3175(B) - Onsemi378
ONSO3305US - Onsemi346
GTS-3DES
FLO-4
US8762658B2
US8533406B2
US9632727B2
KMN-1PROV
PAT-2
PER-8 PROV
PER-9 PROV
INS-4PROV
HAR-1
CES-16
NXT-5PROV NXT-5, 6, 7, 8
IPP-0051-US14 cross roads
FLO-7PROV
IMI-5PROV
IPP-0050-US35 nextremity
VIL-12
OPT-13
TOY-1
US10998041B1
FSP1845
US6559866B2
Placeholder App
PER-10
KBR-1 1400.2.623
PER-13PROV
PAT-3
US20030023453
RMS-1DES
SMG-1DES
FLO-5
US10318495
US10133662B2
PER-11
US20140066758
VIL-17
PER-17
JBR-1
PER-12
US11056880
US11302645
US20210407565
US11081191
PON-1PROV, 2PROV, 3PROV
PER-33
RMT-1PROV
PER-32
PER-34
MCC-1
FLO-10
PER-14
PER-19
PER-22
PER-18
PER-24
TMC-PAT-1
DAR-2
PER-23
TMC-PAT-4
PER-16
PER-4 DIV1
PER-20
PER-21
BRT-PAT-1
TMC-PAT-5
TMC-PAT-6PROV
BRT-PAT-2-PROV
TMC-PAT-7-PROV
FPR-PAT-1-PROV
TMC-PAT-8-PROV
RMT-1
DAR-1PROV
DAR-2PROV
PON-1PROV
PON-2PROV
PON-3PROV
PER-18PROV
TMC-1PROV
TMC-2PROV
PER-13PCT
PER-13
PER-16PROV
PER-14PROV
PER-34PROV
TMC-4PROV
TMC-3
PAS-1PROV
VEH-1
PER-29DES
TEST.001
E2E-TEST.001
TEST-001
TEST-002
TEST-003
TEST-004
ZED006
FSP1011
Application Number
Matter Number
Paragraph Number
141
Content
Next, a parallel distractor 1500 such as the exemplary parallel distractor 1500 illustrated in FIG. 15 is used to distract the first metatarsus 230 relative to the first cuneiform 210. The user slides holes 1502a,b over pins 1280a,b and holes 1502c,d over pins 1280e,f. This causes a desired rotation and translation of the first metatarsus 230 relative to the first cuneiform 210. When a user places the parallel distractor 1500 on over these pins 1280a,b,e,f this forces the cut faces of the two bones to become parallel. Advantageously, the cut faces of the two bones can be forced to become parallel because the position, orientation, and angles of the holes 1278 and/or holes of either or both of the alignment feature 1260a and alignment feature 1260b can be predefined and customized for each patient when the cutting guide 1300 is fabricated. This alignment enables parallel compression of the two bones together using the parallel distractor 1500. Parallel compression enables more effective compression of the two bones together. Next, the space between the resected surfaces of the first cuneiform 210 and the first metatarsus 230 is prepared for fusion. Then, the parallel distractor 1500 is activated such that the first cuneiform 210 and the first metatarsus 230 are fused together.
Reference Case 1
Reference Case 2
Notes
Added by DJM 7 2021
Raw Data
<w:p w14:paraId="144E991E" w14:textId="72FF6951" w:rsidR="006468D8" w:rsidRPr="00B32BBA" w:rsidRDefault="005D5BDF" w:rsidP="00CC46D8"><w:pPr><w:pStyle w:val="NumberedParagraph"/><w:tabs><w:tab w:val="clear" w:pos="360"/><w:tab w:val="num" w:pos="1080"/></w:tabs><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr></w:pPr><w:r w:rsidRPr="00B32BBA"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t>Next, a parallel distractor 1500 such as the exemplary parallel distractor 1500 illustrated in FIG. 15 is used to distract the first metatarsus 230 relative to the first cuneiform 210. The user slides holes 1502a,b over pins 1280a,b and holes 1502c,d over pins 1280e,f. This causes a desired rotation and translation of the first metatarsus 230 relative to the first cuneiform 210</w:t></w:r><w:r w:rsidR="00890BA8" w:rsidRPr="00B32BBA"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t xml:space="preserve">. When a user places the parallel distractor 1500 on over these pins 1280a,b,e,f this forces the cut faces of the two bones to become parallel. </w:t></w:r><w:r w:rsidR="002E6172" w:rsidRPr="00B32BBA"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t xml:space="preserve">Advantageously, the cut faces of the two bones can be forced to become parallel because the position, orientation, and angles of the holes 1278 and/or holes of either or </w:t></w:r><w:proofErr w:type="gramStart"/><w:r w:rsidR="002E6172" w:rsidRPr="00B32BBA"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t>both of the alignment</w:t></w:r><w:proofErr w:type="gramEnd"/><w:r w:rsidR="002E6172" w:rsidRPr="00B32BBA"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t xml:space="preserve"> feature 1260a and alignment feature 1260b can be predefined and customized for each patient when the cutting guide 1300 is fabricated. This alignment enables parallel compression of the two bones together using the parallel distractor 1500. Parallel compression enables more effective compression of the two bones together. </w:t></w:r><w:r w:rsidR="00890BA8" w:rsidRPr="00B32BBA"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t xml:space="preserve">Next, the space between the resected surfaces of the first cuneiform 210 and the first metatarsus 230 is prepared for fusion. Then, the parallel distractor 1500 is activated </w:t></w:r><w:r w:rsidR="002E6172" w:rsidRPr="00B32BBA"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t xml:space="preserve">such </w:t></w:r><w:r w:rsidR="00890BA8" w:rsidRPr="00B32BBA"><w:rPr><w:rFonts w:asciiTheme="minorHAnsi" w:hAnsiTheme="minorHAnsi"/></w:rPr><w:t>that the first cuneiform 210 and the first metatarsus 230 are fused together.</w:t></w:r></w:p>
Submit