Toggle navigation
Dave's Patent Content Factory
Applications
(current)
Terms
Paragraphs
Claims
Docket
logout
about
Edit Paragraph
Application
2380.2.01
US-20150012794-A1
US-20150205664-A1
US-20100023800-A1
US-8737141-A1
US-10157004-B2
US10007433A1
US-9159419-B2
US-10114589-A1
US-10134728-A1
US-20200065270-A1
US-10637533-B2
US-9927986-A1
US-8380915-A1
US-9159419-A1
US-9208071-A1
US-20200098728-A1
US-10643676-A1
US-10468073-B2
US-10283200-A1
US-10461965-B1
US-20130279232-A1
US-8892980-B2
US9632727A1
US10558561A1
US20100023800A1
US7230213A1
OPT-9
FLO-2
FLO-5PROV
ONSO3175(B) - Onsemi378
ONSO3305US - Onsemi346
GTS-3DES
FLO-4
US8762658B2
US8533406B2
US9632727B2
KMN-1PROV
PAT-2
PER-8 PROV
PER-9 PROV
INS-4PROV
HAR-1
CES-16
NXT-5PROV NXT-5, 6, 7, 8
IPP-0051-US14 cross roads
FLO-7PROV
IMI-5PROV
IPP-0050-US35 nextremity
VIL-12
OPT-13
TOY-1
US10998041B1
FSP1845
US6559866B2
Placeholder App
PER-10
KBR-1 1400.2.623
PER-13PROV
PAT-3
US20030023453
RMS-1DES
SMG-1DES
FLO-5
US10318495
US10133662B2
PER-11
US20140066758
VIL-17
PER-17
JBR-1
PER-12
US11056880
US11302645
US20210407565
US11081191
PON-1PROV, 2PROV, 3PROV
PER-33
RMT-1PROV
PER-32
PER-34
MCC-1
FLO-10
PER-14
PER-19
PER-22
PER-18
PER-24
TMC-PAT-1
DAR-2
PER-23
TMC-PAT-4
PER-16
PER-4 DIV1
PER-20
PER-21
BRT-PAT-1
TMC-PAT-5
TMC-PAT-6PROV
BRT-PAT-2-PROV
TMC-PAT-7-PROV
FPR-PAT-1-PROV
TMC-PAT-8-PROV
RMT-1
DAR-1PROV
DAR-2PROV
PON-1PROV
PON-2PROV
PON-3PROV
PER-18PROV
TMC-1PROV
TMC-2PROV
PER-13PCT
PER-13
PER-16PROV
PER-14PROV
PER-34PROV
TMC-4PROV
TMC-3
PAS-1PROV
VEH-1
PER-29DES
TEST.001
E2E-TEST.001
TEST-001
TEST-002
TEST-003
TEST-004
ZED006
FSP1011
Application Number
Matter Number
Paragraph Number
387
Content
During use of the positioning guide 2300, a surgeon may slide the slot 2324 over the posterior pin 2220 and the anterior pin 2222 over the hole 2332. As the positioning guide 2300 slides down the pins (e.g., posterior pin 2220 and anterior pin 2222) the distance between the slot 2324 and the hole 2332 longitudinally may reduce the osteotomy and bring the two bone fragments into contact with each other. Initially, the posterior pin 2220 may be near the dorsal end 2326. A surgeon can then move the posterior pin 2220 toward the plantar end 2328 to rotate the bone fragment engaged by the posterior pin 2220 about its longitudinal axis. The surgeon determines whether the posterior pin 2220 should be moved to near the plantar end 2328, remain near the dorsal end 2326, or some position in between. With the bone fragments connected to the posterior pin 2220 and/or the anterior pin 2222 translated, reduced, and/or rotated, surgeon can then connect the two bone fragments using temporary or permanent fixation hardware and/or techniques. In such an example, a surgeon can predefine (e.g., the length 2330 and/or the slot 2324) how much rotation is desired and/or adjust the amount of rotation intraoperatively to achieve a desired orientation during the surgery.
Reference Case 1
Reference Case 2
Notes
Added by DJM Jan 2024
Raw Data
Submit