Dave's Patent Content Factory
Applications
Terms
Paragraphs
Claims
Docket
Logout
About
Paragraph #14,775
Edit Paragraph
View
List Paragraphs
Delete
Application
2380.2.01
US-20150012794-A1
US-20150205664-A1
US-20100023800-A1
US-8737141-A1
US-10157004-B2
US10007433A1
US-9159419-B2
US-10114589-A1
US-10134728-A1
US-20200065270-A1
US-10637533-B2
US-9927986-A1
US-8380915-A1
US-9159419-A1
US-9208071-A1
US-20200098728-A1
US-10643676-A1
US-10468073-B2
US-10283200-A1
US-10461965-B1
US-20130279232-A1
US-8892980-B2
US9632727A1
US10558561A1
US20100023800A1
US7230213A1
OPT-9
FLO-2
FLO-5PROV
ONSO3175(B) - Onsemi378
ONSO3305US - Onsemi346
GTS-3DES
FLO-4
US8762658B2
US8533406B2
US9632727B2
KMN-1PROV
PAT-2
PER-8 PROV
PER-9 PROV
INS-4PROV
HAR-1
CES-16
NXT-5PROV NXT-5, 6, 7, 8
IPP-0051-US14 cross roads
FLO-7PROV
IMI-5PROV
IPP-0050-US35 nextremity
VIL-12
OPT-13
TOY-1
US10998041B1
FSP1845
US6559866B2
Placeholder App
PER-10
KBR-1 1400.2.623
PER-13PROV
PAT-3
US20030023453
RMS-1DES
SMG-1DES
FLO-5
US10318495
US10133662B2
PER-11
US20140066758
VIL-17
PER-17
JBR-1
PER-12
US11056880
US11302645
US20210407565
US11081191
PON-1PROV, 2PROV, 3PROV
PER-33
RMT-1PROV
PER-32
PER-34
MCC-1
FLO-10
PER-14
PER-19
PER-22
PER-18
PER-24
TMC-PAT-1
DAR-2
PER-23
TMC-PAT-4
PER-16
PER-4 DIV1
PER-20
PER-21
BRT-PAT-1
TMC-PAT-5
TMC-PAT-6PROV
BRT-PAT-2-PROV
71212.157.USU1
FPR-PAT-1-PROV
71212.158.USP1
RMT-1
DAR-1PROV
DAR-2PROV
PON-1PROV
PON-2PROV
PON-3PROV
PER-18PROV
TMC-1PROV
TMC-2PROV
PER-13PCT
PER-13
PER-16PROV
PER-14PROV
PER-34PROV
TMC-4PROV
TMC-3
PAS-1PROV
VEH-1
PER-29DES
TEST.001
E2E-TEST.001
TEST-001
TEST-002
TEST-003
TEST-004
ZED006
FSP1011
GAV-PAT-1-PROV
Matter Number
Paragraph Number
394
Application Number
Reference Case 1
Reference Case 2
Content
FIGs 19A-19C illustrate that the example first resection guide 1822 includes one or more stabilizers 1892 and one or more sights 1894. In the example first resection guide 1822 the bone attachment features 1828 are configured such that holes/openings in the body 1902 are parallel to each other and therefore the pins deployed into these holes are also parallel to each other. Having parallel pins can be advantageous because the parallel pins can enable the first resection guide 1822 to be readily removed by sliding the body 1902 off of the pins. In this manner, the pins can remain in the bone(s) and can serve as reference features. However, the parallel pins can also result in the body 1902 being unstable and moving too much during the osteotomy. For example, the body 1902 may move away from the bone(s) along the pins (a translation referred to as riding up).
Notes
Added by DJM Jan 2024
Raw Data
Submit